ERROR ST JAMES PRECISION : Data Missing (All Channels)
15/07/2022 Power down at some point between last LSO and today
18/07/2022 Power was not tripped at the Fuseboard, tried to access roadside "Lucy Lighting" feeder pillar (54.9701085, -1.6230439) on northbound side of St James Boulevard/Sunderland St NE1 4HZ.
28/07/2022 Finally managed to get lid off roadside pillar. But no 'trip' switch was present - just a mains fuse box, so no indication of power status. Reported to Northern PowerGrid - reference 220728-002468. Northern Powergrid found no problem on the feeder pillar - but found a hidden 6A 240V fuse in the Precision Station that had blown. Order put in for replacement 6A fuses.
03/08/2022 11:33 Fuse delived and replaced. Powered back up gradually, leaving Air Con till last. Nothing tripped or blew the fuses, so still unclear what caused the fault (though suspect Air Con).
This site had its contract renewed from 31st July, but the Sim card had been disabled and needed Acoem to re-enable it.
Should now be reporting data and also backfilling whatever data was stored on the logger.